Gentaur SPARCL
Dog PROCALCITONIN (PCT) SPARCL™ Assay | PCT-SP-4
- SKU:
- 198-PCT-SP-4-GEN
- Availability:
- IN STOCK
Description
PRINCIPLE OF THE ASSAY
The dog PCT SPARCL™1 (Spatial Proximity Analyte Reagent Capture Luminescence, ref 3) assay uses two dog PCT specific antibodies. One is conjugated to horseradish peroxidase (HRP), the other is conjugated to acridan, a chemiluminescent substrate. When the HRP and acridan conjugated antibodies bind to PCT they are brought into close proximity. With the addition of hydrogen peroxide (trigger solution), HRP catalyzes oxidation of proximal acridan molecules causing a flash of chemiluminescence. Acridan conjugated antibodies distant from HRP produce no signal. This principle allows the development of a homogeneous assay that allows rapid measurement of PCT concentrations. Diluted serum samples and standards are mixed with the HRP and acridan-conjugated antibodies in the wells of the 96-well SPARCL™ plate2 provided with the kit. After incubation for 30 minutes on a shaker at 25°C and 150 rpm, the plate is placed into a luminometer. Trigger solution containing hydrogen peroxide is injected into each well and luminescence is immediately measured. The concentration of PCT is proportional to luminescence and is derived from a standard curve.
MATERIALS AND COMPONENTS
Materials provided with the kit:
• Anti-PCT HRP conjugate. Store ≤ -70°C
• Anti-PCT acridan conjugate. Store ≤ -70°C
• Dog PCT stock. Store ≤ -70°C
• Diluent: CSD50-1, 2 x 50 ml
• Trigger solution: TS7-1, 7 ml
• White SPARCL™ plate (12 x 8-well)
• Clear untreated 96-well plate
Materials required but not provided:
• Precision pipettes and tips
• Polypropylene tubes
• Vortex mixer
• Microplate incubator/shaker
• Luminometer capable of simultaneous injection & measurement
• Graphing software
STORAGE
Store the HRP conjugate, acridan conjugate and haptoglobin stock at -70°C (they may be stored at -20°Cfor one week). The remainder of the kit should be stored at 2-8°C. The SPARCL™ plate should be kept in a sealed bag with desiccant and antioxidant. The kit will remain stable for at least six months from the date of purchase, provided that the components are stored as described above
GENERAL INSTRUCTIONS
1. Please take the time to completely read all instructions before starting your assay. Contact us if you need clarification.
2. All reagents used in the assay should be allowed to reach room temperature (25°C) before use.
3. It is important that standards and samples be added to the SPARCL™ plate quickly. If testing large numbers of samples, rather than pipetting standards and samples directly into the white SPARCL™ plate using a single channel pipettor, we recommend the following. First, pipette an excess volume of standards and samples into appropriate wells of the clear 96- well plate. Then use an 8- or 12-channel multipipettor to quickly and efficiently transfer 50 ml aliquots to the appropriate wells of the white SPARCL™ plate. The wells of the clear plate hold a maximum volume of 300 ml.
4. Follow the sequence of events below when running the assay.