Human Autoantibodies against the C-terminal domain 1 (ACAST-D1) ELISA Kit | KTE62606

(No reviews yet) Write a Review
SKU:
749-KTE62606
Availability:
Usually ships in 5 working days
NULL627.00 - NULL1,032.00

Description

Human Autoantibodies against the C-terminal domain 1 (ACAST-D1) ELISA Kit | KTE62606 | Gentaur UK, US & Europe Distribution

Application: This Human Autoantibodies against the C-terminal domain 1 (ACAST-D1) ELISA Kit employs a two-site sandwich ELISA to quantitate ACAST-D1 in samples. An antibody specific for ACAST-D1 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyACAST-D1 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for ACAST-D1 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of ACAST-D1 bound in the initial step. The color development is stopped and the intensity of the color is measured.

Detection Method: Colorimetric

Conjugate: N/A

Sample Type: Cell culture supernatants#Serum#Plasma#Other biological fluids

Assay Type: Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person.

Kit Component: • Human Autoantibodies against the C-terminal domain 1 microplate
• Human Autoantibodies against the C-terminal domain 1 standard
• Human Autoantibodies against the C-terminal domain 1 detect antibody
• Streptavidin-HRP
• Standard diluent
• Assay buffer
• HRP substrate
• Stop solution
• Wash buffer
• Plate covers

Features & Benefits: Human Autoantibodies against the C-terminal domain 1 (ACAST-D1) ELISA Kit has high sensitivity and excellent specificity for detection of Human ACAST-D1. No significant cross-reactivity or interference between Human ACAST-D1 and analogues was observed.

Calibration Range: Please inquire

Limit Of Detection: Please inquire

Usage Note: • Do not mix components from different kit lots or use reagents beyond the kit expiration date.
• Allow all reagents to warm to room temperature for at least 30 minutes before opening.
• Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
• Unused wells must be kept desiccated at 4 °C in the sealed bag provided.
• Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
• It is recommended that all samples and standards be assayed in duplicate or triplicate.

Storage Instruction: The unopened kit should be stored at 2 - 8°C. After opening, please store refer to protocols.

Shipping: Gel pack with blue ice.

Precaution The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product.

Background: The C-terminus (also known as the carboxyl-terminus, carboxy-terminus, C-terminal tail, C-terminal end, or COOH-terminus) is the end of an amino acid chain (protein or polypeptide), terminated by a free carboxyl group (-COOH) . When the protein is translated from messenger RNA, it is created from N-terminus to C-terminus. The convention for writing peptide sequences is to put the C-terminal end on the right and write the sequence from N- to C-terminus.