740
Human High affinity copper uptake protein 1 (SLC31A1) ELISA Kit | AE18728HU
- SKU:
- 740-AE18728HU
- Availability:
- Usually ships in 5 working days
Description
Human High affinity copper uptake protein 1 (SLC31A1) ELISA Kit | AE18728HU | Gentaur UK, US & Europe Distribution
Species Reactivity: Human (Homo sapiens)
Abbreviation: SLC31A1
Alternative Name: COPT1; CTR1; MGC75487; hCTR1; copper transport 1 homolog|copper transporter 1
Application: ELISA
Range: 0.156-10 ng/mL
Sensitivity: 0.055 ng/mL
Intra-Assay: ≤4.3%
Inter-Assay: ≤6.7%
Recovery: 0, 99
Sample Type: Serum, Plasma, Other biological fluids
Detection Method: Sandwich
Analysis Method : Quantitive
Test Principale: This assay employs a two-site sandwich ELISA to quantitate SLC31A1 in samples. An antibody specific for SLC31A1 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anySLC31A1 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for SLC31A1 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of SLC31A1 bound in the initial step. The color development is stopped and the intensity of the color is measured.
Product Overview: Copper is an element essential for life, but excessive copper can be toxic or even lethal to the cell. Therefore, cells have developed sophisticated ways to maintain a critical copper balance, with the intake, export, and intracellular compartmentalization or buffering of copper strictly regulated.The deduced 190-amino acid human CTR1 protein is similar to yeast CTR1 and Arabidopsis COPT1, a copper transporter also isolated by functional complementation of yeast ctr1. All 3 predicted proteins have 3 transmembrane domains and an N terminus that is rich in methionine and serine residues; the N terminus of human CTR1 is also abundant in histidines. Northern blot analysis detected 2 major CTR1 transcripts of approximately 2 kb and 5.5 kb and a less abundant transcript of about 8.5 kb in all human organs and tissues examined.
Stability: The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. The loss rate was determined by accelerated thermal degradation test. Keep the kit at 37°C for 4 and 7 days, and compare O.D.values of the kit kept at 37°C with that of at recommended temperature. (referring from China Biological Products Standard, which was calculated by the Arrhenius equation. For ELISA kit, 4 days storage at 37°C can be considered as 6 months at 2 - 8°C, which means 7 days at 37°C equaling 12 months at 2 - 8°C) .