INTROL® CF Panel III Control

(No reviews yet) Write a Review
SKU:
868-G115-1/G115-GEN
Availability:
IN STOCK
NULL775.00 - NULL1,007.00

Description

INTROL® Cystic Fibrosis Panel III Control

Order Number:

G115-1 contains: 4 bottles, 1 milliliter each

G115 contains: 4 bottles, 2 milliliters each

INTROL® CF Panel III Control DataSheet

INTENDED USE:

INTROL® CF Panel III Control is intended for in vitro use as a quality control to monitor analytical performance of the extraction, amplification and detection steps of systems used in the qualitative measurement of the Cystic Fibrosis Transmembrane Conductance Regulator (CFTR) gene. This product is intended to be extracted and analyzed routinely with each cystic fibrosis (CF) test run.

INTROL CF Panel III is designed to monitor the detection of 79 CFTR mutations, genetic risk factors associated with cystic fibrosis, including the 23 mutations recommended by ACMG and ACOG. INTROL CF Panel III Control also monitors variants I506V, I507V, F508C, 5/7/9/11T and I148T.

INTROL CF Panel III is provided for Research Use Only (RUO). It cannot be cloned, sold, or transferred without the explicit written consent of . Patents issued.

PRODUCT SUMMARY:

INTROL CF Panel III Control consists of synthetic CFTR DNA suspended in a non-infectious, blood-like matrix containing carrier DNA, preservatives and stabilizers. The synthetic DNA contains all 27 CFTR gene exons plus intronic borders, and contains specific mutations and variants which are divided among 4 bottles (Bottles a, b, c, d). Specific mutations and variants present are described in Table 1. The DNA should be extracted and purified from its matrix before analysis.

Analysis of INTROL CF Panel III test results can be valuable in the detection and troubleshooting of errors associated with the sample extraction, amplification, and signal measurement phases of CF test systems.

PRECAUTIONS AND WARNINGS:

This product contains 23% ethanol (v/v) and could be flammable. Keep away from open flames.

This product is intended for in vitro analytical testing and is provided for Research Use Only, not for use in diagnostic procedures. This product does not contain any biological material of human origin.

INSTRUCTIONS FOR USE:

Extract and analyze INTROL CF Panel III Control as you would a whole blood specimen:

  1. Allow INTROL CF Panel III to come to room temperature (18° – 25°C).
  2. Thoroughly mix the solution prior to opening by inverting the bottle several times or placing on an automated mixer immediately before
  3. Extract INTROL CF Panel III in the same manner as a whole blood Use the same volume that would be used for a patient sample in your lab.

Note 1: Certain test methods may require additional processing of control material, such as dilution prior to analysis.

Note 2: The level of CFTR DNA present in the extracted control may not be detectable by certain quantitation methods and is not quantifiable by spectrophotometer measurements.

  1. Analyze the extracted DNA as you would genomic DNA. If dilutions or other preparations of the extracted DNA are required as part of the testing procedure, handle the INTROL CF Panel III DNA in the same manner as clinical
  2. Tightly recap each bottle after use and store refrigerated (2° - 8°C).
  3. Controls should be tested routinely as a matter of Good Laboratory Practice and according to guidelines or requirements of local, state, and/or federal regulations or accrediting The frequency of analysis will depend on individual laboratory policies for control use and may vary according to the analyte being measured or the analytical system being used.

STORAGE:

Upon receipt and after opening, the material should be stored at 2° – 8°C. Do not freeze.

STABILITY:

Unopened INTROL CF Panel III Control material is stable through the expiration date printed on each bottle when stored refrigerated (2° – 8°C). Opened material tightly capped and returned to the refrigerator (2° – 8°C) shortly after use is stable for thirty (30) days from the date of opening.

EXPECTED VALUES:

The genotype for each mutant / variant allele is listed in Table 1 below. The sequence of INTROL CF Panel III DNA has been confirmed by bi-directional sequencing. In some CF test systems, neighboring mutations interfere with expected test results. Such interferences occur with the INTROL CF Panel III just as they occur with patient samples. Thus, INTROL CF Panel III can assist the lab by demonstrating interference results to ensure correct interpretation of results.

The laboratory should follow Good Laboratory Practice (GLP) and establish its own performance characteristics for INTROL CF Panel III in demonstrating adequate system performance. Recoveries may vary depending on extraction method, instrumentation, cycle time / temperature, reagents, method variation, and other systematic or random errors.

Table 1.

INTROL® CF Panel III Control Mutations and Variants [in parentheses ( )].

 

Allele

Genotype

Allele

Genotype

Allele

Genotype

Bottle a

Bottle b

Bottle d

CFTRdele2,3

HET

E60X

HET

R75X

HET

Y122X

HET

G85E*

HET

405+3A>C

HET

(7T*/11T)

7T/11T

(I148T)

I148T/WT

406-1G>A

HET

Q493X

HET

621+1G>T*

HET

444delA

HET

(I507V)*

I507V/WT

711+1G>T*

HET

R117C

HET

(F508C)*

F508C/WT

1078delT

HET

G178R

HET

S549RT>G

HET

R334W*

HET

L206W

HET

A559T

HET

R347P*

HET

935delA

HET

1898+5G>T

HET

(7T*/9T*)

7T/9T

delF311

HET

2307insA

HET

A455E*

HET

G330X

HET

Y1092XC>A

HET

del F508*

HET

R352Q

HET

M1101K

HET

V520F

HET

S364P

HET

3849+4A>G

HET

1717-1G>A*

HET

(5T*/9T*)

5T/9T

S1251N

HET

G542X*

HET

G480C

HET

Bottle c

S549N

HET

del I507*

HET

394delTT

HET

G551D*

HET

1677delTA

HET

R117H*

HET

R560T*

HET

S549N

HET

711+5G>A

HET

1898+1G>A*

HET

1812-1G>A

HET

R347H

HET

2143delT

HET

G622D

HET

(5T*/7T*)

5T/7T

2184delA*

HET

2055del9>A

HET

del I507*

HET

2789+5G>A*

HET

K710X

HET

(I506V)*

I506V/WT

3120+1G>A*

HET

Q890X

HET

1677delTA

HET

3199del6

HET

2869insG

HET

S549RA>C

HET

D1152H

HET

3120G>A

HET

R553X*

HET

R1162X*

HET

R1066C

HET

2183AA>G

HET

3659delC*

HET

W1089X

HET

3272-26A>G

HET

3849+10KbC>T

HET

R1158X

HET

Y1092XC>G

HET

3876delA

HET

S1196X

HET

S1255XA>G

HET

3905insT

HET

3791delC

HET

S1255XC>A

HET

W1282X*

HET

D1270N

HET

 

 

N1303K*

HET

 

 

*ACMG / ACOG Panel

 