321
Testosterone ISWE Mini-Kit - ISWE001
- SKU:
- 321-ISWE001
- Availability:
- Usually shipped in 5 Working Days
Description
The ISWE Testosterone Mini-Kit is specifically designed to measure Testosterone present in a variety of samples and species for wildlife conservation. The end user must provide or coat their own anti-rabbit IgG secondary antibody coated plates, in addition to assay buffer, wash buffer, substrate and stop solution. See Related Products for suitable options available.
NOTE: The 50X Concentrate Rabbit Antibody to Testosterone cannot be directly coated onto plates for EIA use. It is an unpurified serum diluted in a buffer containing proteins and detergents. The antibody WILL NOT bind to uncoated microtiter plates effectively. The end user must use plates coated with goat or donkey anti-rabbit IgG.
Kits include:
ISWE Testosterone Antibody Concentrate
ISWE Testosterone Conjugate Concentrate
Testosterone Standard
Storage Instructions
All components of this kit should be aliquoted into vials upon first thaw. Avoid repeat freeze-thaw cycles.
Store at -20°C until the expiration date of the kit.
Protocols
The rabbit anti-Testosterone is supplied at a 50X concentration. An aliquot should be brought to room temperature and diluted one part with 49 parts of a suitable assay buffer. If your assay buffer has protein, detergent and preservative in it, the diluted antibody will be stable for greater than 1 month at 4°C. Please see Related Products for a suitable Assay Buffer.
The Testosterone-HRP conjugate is supplied at a 50X concentration. An aliquot should be brought to room temperature and diluted one part with 49 parts of a suitable diluent or assay buffer. If you wish to store the diluted conjugate for greater than 1 month at 4°C you should dilute it in a suitable conjugate diluent. Please see Related Materials for a suitable Conjugate Diluent.
The Testosterone standard stock is provided at 1,000 ng/mL (1,000,000 pg/mL) in a special storage solution. The solution contains an organic solvent. Prerinse the pipet tip several times to ensure accurate delivery.
NOTE: The dilution of the ISWE Mini-Kit antibody and conjugate are such that when diluted 1:50 in Assay Buffer or Conjugate Diluent and added to an ’ antibody coated plate, using 50 μL of sample or standards, 25 μL of conjugate and 25 μL of antibody in a 2 hour room temperature with shaking incubation, followed by ’ TMB as substrate, these reagents will generate approximately 1.0 OD at 450 nm. YOUR RESULTS WILL VARY DEPENDING ON A NUMBER OF VARIABLES. You will have to titer the antibody or conjugate to obtain the optimum conditions for your assay system.