Description

Hexanoyl-Lysine (HEL) ELISA kit

Biomarker for early stage of lipid oxidation

Oxidative damage of lipids caused by reactive oxygen species (ROS) play an important role in some diseases, lesion of cell functions and aging. Aldehydes such as malondi-aldehyde (MDA) and 4-hydroxy-2-nonenal (4-HNE) have been reported as one of the advanced lipid peroxidation products. But recently in the earlier stage of lipid peroxidation, 13-hydroperoxyoctadecanoic acid (13-HPODE) is found to be covalently bound to proteins1). Hexanoyl-Lysine adduct (HEL) is a novel lipid hydroperoxide-modified lysine residues. HEL is formed by oxidative modification by oxidized omega-6 fatty acids such as linoleic acid or arachidonic acid. HEL may be a useful biomarker for initial stage of lipid peroxidation.Monoclonal antibodies and ELISA kit have been developped, and HEL can be detected in oxidatively modified LDL, in human atherosclerotic lesions, human urine and serum. It is also reported that HEL is formed in rat muscle during exercise, and the formation is prohibited by antioxidants such as flavonoids.

Hexanoyl-Lys (HEL) ELISA kit

have developed HEL ELISA kit in collaboration with Dr. Toshihiko Osawa (Nagoya University) and Dr. Yoji Kato (Univerisity of Hyogo). This ELISA kit can be applied to urine, serum and cultured cells form human and animal.

Specifications
Assay principle: Competitive ELISA (detection: 450 nm)
Specifity: Specific to N-epsilon-Hexanoyl-Lysine adduct
Measuring range: 2 - 700 nmol/L
Time to answer: Over night and 2 hours.
Format: 96 wells (54 samples in single assay)
Applications: Urine, serum and cultured cells from human and animals.
Storage: Store at 2 - 8°C (don't freeze).
Expiry: 2 years after the day of manufacturing.
Required but not provided: 50 µL micropipettor and pipette tips
8-channel (50-200 µL) micropipettor and tips
8 or 12-syncronous multichannel pipet and reagent tray for multichannel pipet.
4-7 °C incubator
Microtiter plate reader (measuring wavelength 450 nm)
Content of this kit
HEL-coated Microtiter Plate: 1 plate (96 wells)
Primary Antibody (ready to use): 1 vial
Secondary Antibody: 1 vial
Secondary Antibody Buffer: 1 vial
Chromogen (TMBZ solution): 1 vial
Chromogen Buffer: 1 vial
Washing Buffer (5X): 1 vial
Stop Solution: 1 vial
Standard solution (6 levels): 1 vial each
Plate seal: 2 sheets

 

View AllClose

Additional Information

Size:
96 wells
Type of Marker:
Lipid oxidation
Marker:
HEL (13HPODE-Lys adduct)
Storage:
Less than -20°C
Usage:
Tissue
Application:
Immunohistochemistry, western blotting and ELISA.