Description

Human Monkeypox Virus (MPV) ELISA Kit | GEN-MPV-07

Product Short Name: [Monkeypox Virus (MPV)]

Product Name Synonyme: N/A

Other Names: [movement protein; 22 kDa protein; p22 protein; 22 kDa protein]

Product Gene Name: [MPV]

Product Gene Name Synonyme: N/A

Other Gene Names: [G356_gp4]

Clonality: N/A

Isotype: N/A

Clone: N/A

Host: N/A

Reactivity: Human

Specificity: N/A

Purity: N/A

Form: N/A

Concentration: N/A

Storage Stability: Store all reagents at 2-8°C

Tested Application: N/A

 

1. INTENDED USE AND PRINCIPLE OF THE ASSAY

The kit uses a sandwich enzyme-linked immunosorbent assay (ELISA) to qualitatively analyze Human Monkeypox Virus (MPV) in Human serum, plasma. This kit is in vitro research use only! Not for therapeutic or diagnostic applications!

2. SAMPLE COLLECTION AND STORAGES

Serum - Centrifuge serum for approximately 20 minutes at 1000 × g (or 3000 rpm) within 30 minutes after collection. Collect the supernatants carefully, assay immediately or store samples at -20°C or -80°C. Avoid repeated freeze/thaw cycles.
Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for approximately 20 minutes at 1000 × g (or 3000 rpm) within 30 minutes after collection. Collect the supernatants carefully, assay immediately or store samples at -20°C or -80°C. Avoid repeated freeze/thaw cycles.
Other biological fluids - Remove particulates by centrifugation (approximately 20 minutes at 1000 × g (or 3000 rpm) within 30 minutes after collection) and assay immediately or store samples at -20°C. Avoid repeated freeze-thaw cycles.

3. SAMPLE PREPARATION

Serum and plasma to be used within 7 days may be stored at 2-8°C otherwise samples must be stored at -20 or -80°C to avoid loss of bioactivity and contamination. Avoid freeze-thaw cycles. When performing the assay slowly bring samples to room temperature. The samples should be centrifugated adequately, and hemolyzed samples or samples with granules are not suitable for use in this assay.

4. MATERIALS SUPPLIED

Items Materials Color of covers 48 well kit 96 well kit
1 Microelisa Stripplate --- 48 well plate 96 well plate
2 Positive Control Red 0.5ml/vial 0.5ml/vial
3 Negative Control Green 0.5ml/vial 0.5ml/vial
4 Sample Diluent Blue 3.0ml×1 bottle 6.0ml×1 bottle
5 HRP-conjugate Reagent Red 5.0ml×1 bottle 10.0ml×1 bottle
6 20X Wash solution White 15ml×1 bottle 25ml×1 bottle
7 Chromogen Solution A Purple 3.0ml×1 bottle 6.0ml×1 bottle
8 Chromogen Solution B Black or Brown 3.0ml×1 bottle 6.0ml×1 bottle
9 Stop Solution Yellow 3.0ml×1 bottle 6.0ml×1 bottle
10 Closure Plate Membrane --- 02 x pieces 02 x pieces
11 Manual --- 1×paper 1×paper

 

5. PRECAUTIONS

  1. The operation should be carried out in strict according to the instructions.
  2. Avoid cross-contamination when changing tips, and pipette reagents and samples into the center of each well.
  3. The samples should be transferred into the assay wells within 15 minutes.
  4. If the blue color too shallow after 15 minutes incubation with the substrates, it may be appropriate to extend the incubation time.
  5. Do not mix the reagents from different batches
  6. Chromogenic Substrate B is light-sensitive, please avoid prolonged exposure to light.

 

6. MATERIALS REQUIRED BUT NOT SUPPLIED

  1. Distilled water.
  2. Absorbent papers or paper towels.
  3. Pipettes and disposable pipette tips.
  4. An ELISA reader capable of measuring absorbance at 450 nm.
  5. An incubator which can provide stable incubation conditions up to 37°C±0.5°C.

7. WASHING METHOD

Manual Washing - Dump the incubation mixtures of the wells into a sink or proper waste container. Using pipette or squirt bottle, fill each well completely with Wash Solution (1×), after about one minute's standing, invert and hit the Plate onto absorbent papers or paper towels until no moisture appears. Repeat this procedure four times. Note: Hold the sides of the Plate frame firmly when washing the Plate to assure that all strips remain securely in frame.

Automated Washing - Aspirate all wells, then wash the Plate four times using Wash Buffer (1×). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350Fl/well/wash. After final wash, invert the Plate, and blot dry by hitting the Plate onto absorbent paper or paper towels until no moisture appears.

8. Storage
Please store the Plate and all reagents at 2°C-8°C.

  1. The valid period of this kit is six months at 2°C - 8°C. The kit should not be used beyond the expiration date.
  2. Wash Solution (1×) - Dilute one volume of Wash Solution (20×) with nineteen volumes of deionized or distilled water.
  3. Diluted Wash Solution is stable for one month at 2°C - 8°C. Undiluted Wash Solution and other reagents are stable for six months at 2°C - 8°C.
  4. When the kit is opened, please used up all the Plate as soon as possible after removed the Plate from the foil pouch.
  5. The Plate is detachable, so please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal for preventing damps. The remaining reagents still need to be stored at 2°C - 8°C.

9. ASSAY PROCEDURE

1. First, check the Plate and equipment before your experiments and make sure they are no problem, check the labels and the color of the covers of the vials/bottles and make sure they are matched and no mistake. Bring all reagents and samples to room temperature (18°C-25°C) naturally for 30min before starting assay procedures. DO NOT use hot water baths to thaw samples or reagents. If necessary, doing a low - speed centrifugation for one or two seconds to concentrate the Positive/Negative Controls to the bottom of the vials. The Plate is detachable, detach unused strips from the Plate frame, return them to the foil pouch with the desiccant pack, and reseal for preventing damps.

2. Set Positive Control wells, Negative Control wells and Sample wells. Add Positive Control 50Fl to each Positive Control well, add Negative Control 50µL to each Negative Control well. Add sample 50µL to each Sample wells. Note: This kit is designed to be used with undiluted samples.

 

PC: Positive Control; NC: Negative Control; S01 - 99E Sample

3. Add 100Fl of HRP-conjugate reagent to Positive Control wells, Negative Control wells and Sample wells, cover with an adhesive strip and incubate for 60 minutes at 37°C.

4. Wash the Plate 4 times.

5. Add Chromogen Solution A 50Fl and Chromogen Solution B 50Fl to each well successively. Gently mix and then protect from light to incubate for 15 minutes at 37°C.

6. Add 50µL Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the Plate to ensure thorough mixing.

7. Read the Optical Density (O.D.) at 450 nm using an ELISA reader within 15 minutes after adding Stop Solution (Around 5 minutes is the best time.).

10. DETERMINE THE RESULT

  1. The average of the Positive control well is typically ≥1.0; the average of the Negative control well is typically ≤0.15.
  2. Actual OD values of the Positive and Negative control wells may vary depending on the assay conditions.
  3. Cut-off values were the average of the Negative control well +0.15 in samples tested by the laboratory.

Each researcher should determine their own cut-off values for their samples.

11. ASSAY PERFORMANCES

Intra-assay CV (%) and Inter-assay CV (%) are less than 15%.

 

View AllClose

5 Reviews

  • 4
    obrigated

    Posted by Easton on 15th Sep 2022

    Quality and exchange of a product are totally obrigated. Only Genatur provides this service

  • 4
    Fastest delivery

    Posted by Axel on 15th Sep 2022

    The parcel was delivered before the last date which surprised me so much because mostly a customer usually do not get the parcel before the deadline date but after buying a product from this company my stereotype has changed. Thanks!

  • 4
    Amazing

    Posted by Santiago on 15th Sep 2022

    The fastest delivery and the fair prices of the products amazed me so much that I am now fully satisfied with the quality and service of the Gentaur

  • 4
    Excellent

    Posted by Jonathan on 15th Sep 2022

    The response from the company, the shipping, and the packaging were all very excellent and I really recommend their products to others. Thanks for such a wonderful experience.

  • 5
    Speedy delivery

    Posted by Hunter on 15th Sep 2022

    as compared to others they deliver in time. I was not expecting such speedy delivery I was shocked when I got my parcel on time

View AllClose