Mouse Myogenic factor 6 (MYF6) ELISA Kit | AE60381MO | Gentaur UK, US & Europe Distribution

Species Reactivity: Mouse (Mus musculus)

Abbreviation: MYF6

Alternative Name: MRF4; bHLHc4; herculin|myogenic factor 6|myogenic factor-6

Application: ELISA

Range: 0.156-10 ng/mL

Sensitivity: 0.057 ng/mL

Intra-Assay: ≤6.2%

Inter-Assay: ≤11.3%

Recovery: 1, 06

Sample Type: Serum, Plasma, Other biological fluids

Detection Method: Sandwich

Analysis Method : Quantitive

Test Principale: This assay employs a two-site sandwich ELISA to quantitate MYF6 in samples. An antibody specific for MYF6 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyMYF6 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for MYF6 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of MYF6 bound in the initial step. The color development is stopped and the intensity of the color is measured.

Product Overview: MYH6encodes the alpha heavy chain subunit of cardiac myosin. The gene is located 4kb downstream of the gene encoding the beta heavy chain subunit of cardiac myosin. Mutations in this gene cause familial hypertrophic cardiomyopathy and atrial septal defect 3. Unlike the hemoglobin and immunoglobulin examples in which switches are unidirectional--a gene switched off in a terminally differentiated cell cannot be switched on again--the beta-MYHC gene can be switched on again either spontaneously in older animals or experimentally in response to thyroid hormone depletion/replacement or different mechanical stimuli. The alpha-MYHC gene is expressed also in atrial muscle and the beta-MYHC gene in skeletal slow-twitch muscle.

Stability: The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. The loss rate was determined by accelerated thermal degradation test. Keep the kit at 37°C for 4 and 7 days, and compare O.D.values of the kit kept at 37°C with that of at recommended temperature. (referring from China Biological Products Standard, which was calculated by the Arrhenius equation. For ELISA kit, 4 days storage at 37°C can be considered as 6 months at 2 - 8°C, which means 7 days at 37°C equaling 12 months at 2 - 8°C) .